Specification

  • Primary: 10-0-200-220-240 VRMS 50/60Hz.
  • Output: Mull 3-3 300-0-300 VRMS 80mA DC 6.3ct 2A.
  • Construction: Iron Laminated. Double insulated.
  • Treatment: Vacuum Varnish Impregnated.
  • Application: HT Anode and Heater supplies.
  • Range: Standard.

Mounting Arrangement

Picture:dpm12798.gif

Mechanical Dimensions

  • Size (SZ) = Patt29x1/1/2 DT.
  • Width (W) = 3 inch(76mm).
  • Depth (D) = 2 1/2 inch(64mm).
  • Height Above (HA) = 2 3/8 inch(60mm).
  • Height Below (HB) = 5/8 inch(16mm).
  • Fix Centres (FWxFD) = 2 1/2 inch x 2 inch(64mm 51mm).
  • Cutout Hole (CWxED) = 2 1/4 inch x 2 3/8 inch(58mm x 61mm) ES.
  • Fix Size (FZ) = 3/16 inch(M4).
  • Weight (WT) = 2lb 10oz(1.2KG).

Circuit

Picture:dpe12581.gif Picture:dpe12582.gif Picture:dpe12734.gif

Connections

Function Connection
10 Volts Pin 13
0 Volts Pin 14
200 Volts Pin 16
220 Volts Pin 17
240 Volts Pin 18
HT Anode A Pin 12
HT Centre(Ground) Pin 11
HT Anode B Pin 10
Heater A Pin 9
Heater Centre Pin 8
Heater B Pin 7

Connection Layout

Picture:dpm14572.gif

Below


Application Notes


  • Safety note: Warning. This part may be connected to high voltage. Disconnect then discharge for 5 minutes before working on circuit.
  • See also Links on Left of this page.